Opis
Key Features
- Professional and powerful class D amp
- High dynamic range and low distortion
- 2x 2500W / 4ohm high power channels
- 4x 800W / 4ohm mid power channels
- Fully programmable touch screen DSP
- Mute buttons on the front panel
- 2x SUB out to connect active subs
- Fully self-protected for SMPS and channels
- 85-264Vac Universal mains
- Solid construction for 19” 3U rack mount
Tech Specs
Type | Class D amplifier | |
No. of Channels | 6 | |
RMS Power @ 8Ω / 1kHz / 0.1% THD | 2x 1500W + 4x 400W @ 8ohm | |
RMS Power @ 4Ω / 1kHz / 0.1% THD | 2x 2500W + 4x 800W @ 4ohm | |
Gain | High power ch: 32dB Mid power ch: 26dB | |
Signal-to-noise ratio | > 120dB (A-weighted, 20Hz – 20kHz, 8ohm load) | |
Other Features | High power ch: 160Vp / 320 Vpp unloaded Mid power ch: 80Vp / 160 Vpp unloaded | |
Frequency Range | 20Hz – 20kHz (+0/-0,25dB, 8ohm load, 3dB below rated power) | |
Damping Factor | > 1000 (8ohm load, 1kHz and below) | |
Inputs | 2x 3p Female XLR | |
Outputs | 2x 3p Male XLR – LINK 2x 3p Male XLR for active sub 6x Speakon NL4® for speakers | |
Controls | Adjustable by fully programmable DSP (touch screen) 96KHz sampling frequency 24 bit AD/DA converter 32 bit DSP processor | |
Indicators | Signal and Mute per channel | |
Cooling | 2x 80mm / 5V variable speed fan | |
Protections | Input limiter, short circuit, DC of output Under & over voltage, power stage overload Temperature protection of transformer & heat-sinks | |
Power Consumption | UREC™ universal & regulated SMPS | |
Operation Voltage | 85-268V ac Universal mains | |
Connectors | Neutrik® powerCON, Power-in/Power-out | |
Other Features | Rugged and solid steel construction, AL front panel | |
Other Features | Electrostatic black powder coating | |
Dimensions (WxHxD) | 3RU – Rack 19″ 482x132x495mm | |
Weight | 17Kg 37.48lb |